Veri-Flame Web Promo

 

The Eclipse Veri-Flame. . .

             

URGENT Eclipse Safety Notice & Replacement Information

Veriflame.jpg (10718 bytes)

 

The Veri-Flame is a single burner control for monitoring and controlling the startup and shutdown sequence of individual burners. Three basic models are available – Purge, No-purge, and Modulation. Variations within these basic models allow different flame sensing inputs including Ultra-Violet Scanners, Self-Check Scanners, Solid-State UV-IR scanners, IR scanners, and flame rods.

scanners.gif (4924 bytes)

 

Links to PDF files

Veri-Flame Color Bulletin Solid State UV/IR Scanner, 5600-92SC
Veri-Flame Instruction Manual Self Check UV Scanner, 5602-91
90° UV Scanner, 5600-90A UV Scanner, 5600-91

For model selection, pricing and delivery information contact:

Clay Dellinger

Tel: 804-236-3800

Fax: 804-236-3882

veriflame@peconet.com


For specific engineering details contact:
techsupport@peconet.com
or view the Veri-Flame Instruction Manual online (PDF).


The charts below provide a quick cross-reference to industry standard models and components.

Honeywell Cross Reference Fireye Cross Reference

 

Questions and Answers:

Q: Can I use an Eclipse UV scanner with another manufacturer’s series control?

A: No, these units are built to specific safety standards and are tested and approved by listing agencies such as UL, CSA, and FM. Differences in amplifier and tube technologies will not provide approved or safe operation when a component from one manufacturer is mixed with a component from a different manufacturer.

Q: Will the Eclipse unit plug directly into another manufacturer’s base?

A: No, you will need to change the wiring base. Refer to our wiring cross-reference tables for the more common models.

Q: I am using 2 UV scanners in parallel to monitor the burner flame at separate positions; can the Eclipse unit also do this?

A: Yes, our straight UV scanner, part number 49600-91, may be connected in parallel.

Q: What is the difference between the 5602 and 5605 models?

A: The 5602 models have Canadian and US approvals with their shorter “trial-for-ignition” times of 5 or 10 seconds (DIP-switch selected). The 5605 models have longer “TFI” times of 10 or 15 seconds with US approvals only.

Q: Does the Veri-Flame have CE approval?

A: No, these models are not currently available with the CE marking.

Honeywell Cross Reference Chart

Model

Description

Replace With/Alternate

Scanners

Accessories

NO-PURGE System

RM7890A1015
used with>>>
Control,
No-Purge
VF560232AA VF560532AA 49600-90 or -91 UV Scanners 22194
(49602-10); 49602-10-1
R7849A1023 Amplifier, UV
R7849B1021 Amplifier, UV Amplicheck
NO-PURGE System with Self-Check Scanner
RM7890B1014
used with>>>
Control,
No-Purge, Shutter
VF560232AA VF560532AA 49602-91 self check scanner 22194
(49602-10); 49602-10-1
R7847C1005 Amplifier, Shutter C7012E
R7861A1026 Amplifier, Shutter C7061A
PURGE System
RM7895D1011
used with>>>
Control,
Purge
(incl. shutter)
VF560222AA VF560522AA 49600-90 or -91 UV scanners 22194
(49602-10); 49602-10-1
R7849A1023 Amplifier, UV
R7849B1021 Amplifier, UV Amplicheck
R7847C1005 Amplifier, Shutter C7012E 49602-91 self check scanner 49602-91-7 cable
R7861A1026 Amplifier, Shutter C7061A
MODULATING System
RM7840G1014
used with>>>
Control, Modulation (no display) VF560222AA VF560522AA 49600-90 or -91 UV Scanners 22194
(49602-10); 49602-10-1
R7849A1023 Amplifier, UV
R7849B1021 Amplifier, UV Amplicheck
R7847C1005 Amplifier, Shutter C7012E 49602-91 self check scanner 49602-91-7 cable
R7861A1026 Amplifier, Shutter C7061A
EQUIVALENT COMPONENTS - Eclipse components cannot be used with Honeywell units, the entire system must be replaced
R7847A1082 Amplifier, FR Use VF560x-x3AA, with appropriate base
R7847B1072 Amplifier, FR Amplicheck Use VF560x-x3AA, with appropriate base
R7849A1023 Amplifier, UV see system list above
R7849B1021 Amplifier, UV Amplicheck

see system list above

R7847C1005 Amplifier, Shutter C7012E

see system list above

R7861A1026 Amplifier, Shutter C7061A

see system list above

R7851B1000 Amplifier, SS-UV, Amplicheck Use VF560x-x7AA + 21349 solid state + base
ST7800A1039 Purge module, typical Use purge style Veri-Flames
Q7800B1011 Base, burner mounted 22194;49602-10
Q7800A1005 Base, panel mounted 49602-10-1
C7027A1023 Scanner, Straight, 1/2" 49600-91
C7035A1023 Scanner, Straight, 1" 49600-91 (plus adapter 1/2"M to 1"F) 
C7012E1112 Scanner, Self-Check 49602-91 + 49602-91-7
C7061A1004 Scanner, Self-Check 49602-91 + 49602-91-7
C7927A1016 Scanner, Solid State 21349 solid state UV/IR
C7015A1076 Scanner, IR 49600-92
S7800A1001 Display 20896 (or 20316+20317) and 20318
Remote Display Accessories:
221818A Cable 20318 cable
203765 Bracket included with display

 

Fireye Cross Reference Chart

Model

Description

Replace With/Alternate

Scanners

Accessories

NO-PURGE System
MEC120, MEP100, 61-3060 Control, No-Purge VF560232AA, VF560532AA   22194 (49602-10); 49602-10-1

used with

MEUV1 Amplifier, UV   49600-90 or -91 UV Scanners  
MEUVS1 Amplifier, UV Self-check   49602-91 self check scanner 49602-91-7 cable
PURGE System
MEC120, MEP230, 61-3060 Control, Purge  VF560222AA, VF560522AA   22194 (49602-10); 49602-10-1

used with

MEUV1 Amplifier, UV   49600-90 or -91 UV Scanners  
MEUVS1 Amplifier, UV Self-check   49602-91 self check scanner 49602-91-7 cable
MODULATING System
E110, EP160, 60-1466-2 Control, Modulation (no display) VF560222AA, VF560522AA   22194 (49602-10); 49602-10-1
used with        
EUV1 Amplifier, UV   49600-90 or -91 UV Scanners  
EUVS4 Amplifier, UV Self-check   49602-91 self check scanner 49602-91-7 cable
EQUIVALENT COMPONENTS - can not use Eclipse components with Fireye units, entire system must be replaced
61-3060 Base, burner mounted 22194;49602-10
61-5042 Base, panel mounted 49602-10-1
60-1466-2 Base, modulating model 49602-40
UV1A Scanner, Straight, 1/2" 49600-91
UV8A Scanner, 90 degree 49600-90
45UV5 Scanner, Self-Check 49602-91 + 49602-91-7
48PT1/2 Scanner, IR 49600-92 
ED510 Display 20896 (or 20316+20317) and 20318 

 

CALL NOW TO SEE HOW THE VERI-FLAME CAN WORK FOR YOU
804-236-3800
VERIFLAME@PECONET.COM

 

[Eclipse Product Page] [HOME]

[Brochures] [Products] [Hot Stuff] [Services] [Contact] [Related Links] [Tech Bulletins]

©2007 Power Equipment Company
2011 Williamsburg Road Richmond, VA 23231
804-236-3800 Fax 804-236-3882
sales@peconet.com
SITE MAP
Terms & Conditions